ISPUB.com / IJPM/5/2/9006
  • Author/Editor Login
  • Registration
  • Facebook
  • Google Plus

ISPUB.com

Internet
Scientific
Publications

  • Home
  • Journals
  • Latest Articles
  • Disclaimers
  • Article Submissions
  • Contact
  • Help
  • The Internet Journal of Pulmonary Medicine
  • Volume 5
  • Number 2

Original Article

The Effect Of Varying Inspiratory Flow Waveforms On Alveolar Peak Airway Pressure And Intrinsic Positive End Expiratory Pressure In Mechanically Ventilated Patients

R Barrera, N Gabovich, H Sogoloff, J Groeger, S Miodownik

Keywords

decelerating waveform., inspiratory waveforms, intrinsic peep

Citation

R Barrera, N Gabovich, H Sogoloff, J Groeger, S Miodownik. The Effect Of Varying Inspiratory Flow Waveforms On Alveolar Peak Airway Pressure And Intrinsic Positive End Expiratory Pressure In Mechanically Ventilated Patients. The Internet Journal of Pulmonary Medicine. 2004 Volume 5 Number 2.

Abstract


Purpose: To prospectively evaluate peak airway pressure (PaW) intrinsic PEEP (PEEPi), extrinsic PEEP (PEEPe) and peak expiratory flow rate (PEFR) with changing inspiratory flow waveforms during mechanical ventilation in patients.

Material And Methods: Ten critically ill mechanically ventilated patients on controlled mechanical ventilation (CMV) with acute respiratory failure admitted to the intensive care unit were evaluated to assess the effects of decelerating, square and sine waveforms on). PaW, PEEPi, PEEPe, PEFR

Results: PaW was lower with the decelerating waveform compared to square and sine There was no statistical difference in PEEPi, PEEPe or PEFR with varying inspiratory flow waveforms..

Conclusions: Adjustment of inspiratory flow waveforms does not affect PEEPi. A lower PaW coupled with a stable PEEPi makes the decelerating waveform preferred for mechanically ventilated critically ill patients on CMV.

 

Introduction

Clinicians have become increasingly aware of the importance of delivering effective mechanical ventilation while trying to avoid injury associated with different modes. Research has examined untoward effects of certain variables of mechanical ventilation including tidal volume (Vt), intrinsic and extrinsic positive end expiratory pressure (PEEPi and PEEPe) and respiratory rate (RR) (1,2,3,4,5,6). Air trapping and breath stacking often cause development of an increased PEEPi, adverse effects include: altered mechanical ventilation measured variables, hemodynamic compromise, misreading of central venous and pulmonary artery catheter pressure measurements. Other effects are erroneous calculations of static respiratory compliance and increases in work of breathing, which could delay weaning from the ventilator. (7,8,9,10,11,12,13,14) Less obviously, the effect of pressure variation of the inspiratory waveform has been implicated in shear stress damage at the alveolar and lung parenchymal level possibly resulting in a cytokine cascade capable of damaging other organ systems.

Modeling of the lung as a simple electrical capacitance to simulate lung compliance and an electrical resistance as an analog for airway resistance (15) (Fig1) indicates that, at lower respiratory frequencies, levels of PEEPi sould be independent of the applied inspiratory waveform. The integrating properties of the compliance and resistance should, theoretically, achieve the same peak inspiratory pressure and PEEPi as long as Vt is the same, and expiratory time is sufficient to prevent breath trapping. This might suggests that the inspiratory waveform should confer no therapeutic advantage with respect to PaW and PEEPi.

Figure 1
Figure 1: A simple electrical analog model of the lung and airways composed of fixed a fixed airway resistance and lung compliance independent of the applied waveform (the mean airway pressure should be the same).

Figure 2
Figure 2: Airway resistance may be flow sensitive and exhibit dynamic characteristics that are flow dependent. This could explain why the decelerating flow waveform might generate less harmful effect within the lung.

Studies on varying inspiratory waveform patterns in mechanically ventilated patients and their effect on gas exchange, respiratory mechanics and hemodynamic parameters, however, have been scarce and largely inconclusive. Different waveforms might have deleterious effects on respiratory mechanics by altering other respiratory parameters such as PaW, PEEPi, PEEPe and peak expiratory flow rate (PEFR).

This study seeks to evaluate the effects of three different inspiratory flow waveforms on PaW, PEEPi, PEEPe and PEFR in critically ill mechanically ventilated patients with acute respiratory failure on controlled mechanical ventilation (CMV) and to assess the adequacy of the electrical lung model in this type of application.

Materials And Methods

Ten mechanically ventilated patients with acute respiratory failure admitted to the intensive care unit (ICU) of a teaching hospital were evaluated and selected to enter this observational study. The Critical Care and Anesthesia Research Committee conferred approval to evaluate accepted techniques of mechanical ventilation support. This study did not require randomization. All patients were orotracheally intubated with Sheridan low-pressure cuffed endotracheal tubes varying in internal diameters from 7 to 9 mm. An esophageal balloon was positioned in the lower third of the patient's esophagus (35 to 40 cm mark from the nose) and connected to a Bicore CP-100 Pulmonary Monitor (Allied Healthcare Products, Irving, CA). Chest radiographs and negative esophageal pressure deflection during inspiration determined adequacy of placement. All patients were afebrile, spontaneously breathing and connected to a Puritan Bennett 7200AE (Pleasanton, CA) with the following settings: volume-cycled ventilator in the controlled mechanical ventilation mode of operation, tidal volume of 6 ± 1 mL/kg, a respiratory rate of 10 breaths/minute, FiO2 of 0.40 and PEEP of 10 cm H2O or less. Pressure sensitivity trigger was reduced to 2 cm H2O. All patients were mechanically ventilated for less than one week at initiation of the study. All parameters were recorded by the Bicore Pulmonary Monitor. The parameters measured were: minute ventilation (Ve), respiratory rate RR (breaths/ minute), PEEPi, PEEPe, PEFR, mean airway pressure (PaW), change in airway pressure (dpaW).

The patients were randomly placed on each flow pattern for an equilibration time of 5 minutes, then data were collected on each waveform for 2 minutes, downloaded for analysis by the Bicore CP-100 conversion program and loaded to an IBM-PC (CP-100 CVT1.2, Bicore Monitor System). This program converts a binary data file produced by the CP-100 monitor-logging program to an ASCII format parameter file for use with any spreadsheet program. For every patient a mean and standard deviation for every variable was calculated. The initial peak flow was adjusted to attain a constant mean airway pressure (MAP) for the three different waveforms. The inspiratory/expiratory ratio was maintained in a range of 1:2-1:3.

Patients excluded from this study were those with previous esophageal surgery, known abnormal esophageal anatomy and any contraindication to placement of a naso-gastric tube. Data are presented as mean ± standard deviation (SD). Statistical analysis was performed using analysis of variance (ANOVA) and a nonparametric Wilcoxon test (Kruskal-Wallis χ2-test) with a general regression linear model. A value of p ≤ 0.1 was considered statistically significant.

Results

Ten critically ill mechanically ventilated patients with acute respiratory failure were evaluated. Their mean age was 61 ± 12 years (range 35 to 77 years). The causes of respiratory insufficiency were complications of thoracic surgery in five cases, gastric resection in one case, genitourinary surgery in one case and one a complication of breast surgery. All ten patients remained hemodynamically stable during the trial period. Respiratory variables of each patient measured on three different inspiratory flow waveform patterns were compared. Variables are shown in Table 1.

Figure 3
Table 1: Mean and SD of respiratory variables with varying inspiratory flow waveforms.

PaW and dpaW were lower with decelerating waveform (p<0.05).There was no statistically significant change in PEEPi, PEEPe or PEFR with variation in inspiratory flow waveform. Ve and RR were equal in all the experiments (volume-controlled ventilation). There were no statistically significant differences between the square and sine waveforms in other pulmonary mechanics parameters.

Discussion

All three inspiratory waveforms applied to assist patients with respiratory failure did not increase PEEPi. No significant differences were noted in PEFR among the three waveforms. Some studies in the past have suggested that there are no significant differences in efficacy of gas exchange (16,17,18,19,20,21) or hemodynamics (18,19,20,21,22,23) among different waveforms. Other studies have demonstrated improved cardio-respiratory function, including improved gas exchange and respiratory mechanics, with the decelerating inspiratory flow waveform ventilation in normal and diseased lungs compared with the accelerating or constant waveforms (16,19,21,22,23,24,25,26). In theory, the sine waveform is the most physiologic in terms of efficiency and energy expenditure in healthy lungs. The decelerating waveform, however, seems to be advantageous with increasing respiratory requirements because the respiratory compliance is improved. A clinical study demonstrated that the use of the decelerating waveform may have beneficial clinical implications in critically ill mechanically ventilated patients with acute respiratory failure because it improved pulmonary mechanics (16). We previously described that the peak airway pressures were significantly lower using the decelerating inspiratory flow waveform and that dynamic compliance improved compared with the other waveforms (7).

The difficulty in measuring airway pressure should not be underestimated. Direct alveolar pressure measurement under flow conditions is technically challenging and impractical in the clinical setting. Furthermore the readouts provided by mechanical ventilators can at times be confusing due to interchangeable terms used. These measurements represent pressures measured at the proximal end of the endotracheal tube and can be misleading if interpreted as alveolar pressure. The dynamics of gas flow though the airways manifest non-intuitive pressure effects at the alveolar level. Significant to our study was the method used to measure the various airway pressures encountered. The Bicore device measures airway pressures by the use of an esophageal balloon positioned within the thoracic cavity and better represents intra pleural and airway pressures at the alveolar level. These pressures are, furthermore, measured dynamically as opposed to some methods that require special airway maneuvers to elude these values (30). Consequently, PaW, and PEEPi can be more accurately observed while varying the inspiratory waveform parameters. A randomized and comparative trial of fifty-four patients with COPD was performed applying constant, decelerating, and sine waveforms in a random order. The decelerating waveform produced statistically significant reductions of peak inspiratory pressure, mean airway resistance, physiologic dead space ventilation (31). There was also a significant increase in alveolar-arterial oxygen pressure difference with the decelerating flow waveform, but there were no significant changes in pulmonary variables and other hemodynamic measurements. The most favorable flow pattern for ventilated patients with COPD appeared to be the decelerating waveform. In an additional study on ten chronic obstructive pulmonary disease patients receiving mechanically ventilation for acute respiratory failure ventilated with a constant or a decelerating inflation flow profile; tidal volume and respiratory frequency were similar during the experimental conditions. The authors concluded that the inspiratory waveform profile had no significant cardiorespiratory effect in intubated COPD patients mechanically ventilated for acute respiratory failure. (32) Patients with obstructive lung disease are particularly prone to developing PEEPi and therefore have difficulty triggering the ventilator. At constant PEEPi, the decelerating and the two other waveforms did not impair alveolar recruitment. In a study by Nilsestuen, et al, respiratory rate and tidal volume were fairly similar and constant throughout the study. The authors concluded that bedside evaluation for the presence of PEEPi should be routinely performed and corrective adjustments made when appropriate (33)

A protective ventilatory strategy that uses a low-tidal volume and repetitive alveolar recruitment-derecruitment decreased pulmonary and systemic cytokines and, more importantly, decreases mortality (2,29). At the same time, lower tidal volume ventilation is one of the strategies that might increase PEEPi in mechanically ventilated patients (30). A study conducted by de Durante and coworkers demonstrated that the ventilatory settings employed in the ARDSNet low Vt group may generate an auto-PEEP of 5.8 ± 3 cmH2O. These findings suggest that patients with ARDS, ventilated at relatively high respiratory rates develop greater PEEPi than when ventilated at lower rates, even for the same minute ventilation. This mechanism may produce decreased lung injury secondary to recruitment–derecruitment, and hence provides a plausible explanation for some of the decreased mortality observed in the ARDSNet trial in the 6 ml/kg group (34). Vieillard Baron and coworkers investigated the effects of increasing respiratory rate from 15 to 30 breaths/min, while maintaining a constant plateau pressure. Those authors reported a PEEPi of 6.4 ± 2.7 cmH2O at 30 breaths/min, which was associated with an increased right ventricular outflow impedance and a decreased cardiac index. The authors concluded that, in acute lung injury ARDS patients, the use of higher respiratory rate at constant plateau pressure in order to increase minute ventilation is unable to improve elimination of carbon dioxide, while it generates auto-PEEP (35). It is possible to speculate that the observed difference in survival could be related to the difference in total PEEP. (36) The ARDSNet findings pertains to the possible role of PEEPi causing the observed difference in mortality between different tidal volume strategies.

In our study, both lower PaW and dpaW were generated by the decelerating waveform compared to sine and square waveforms, while the mean airway pressure was kept constant at all flow patterns. The lower peak pressure during ventilation suggests a flow mediated airway resistance, which can be accounted for by a high initial peak flow followed by an even distribution of ventilation. A partial narrowing of some portion of the conducting airways during the higher initial flow of the decelerating waveform may be responsible for this. This is comparable in effect to the changes in airway resistance that occurs during expiratory flow and may account for the hysteresis observed in the flow-volume loop across the respiratory cycle. A simple electrical analog model of the lung and airways composed of a fixed airway resistance and lung compliance independent of the applied waveform will result the mean airway pressure to be the same. These results show that any simple electrical model used to describe this requires modification as an explanatory tool for understanding the differences between the various inspiratory waveforms. An alternative model of airway resistance may be flow sensitive and exhibit dynamic characteristics that are flow dependent. This could explain why the decelerating flow waveform might generate less harmful effect within the lung. More interesting, perhaps, are the findings with regard to dpaW. This parameter may relate more closely to the physical excursions that alveoli undergo during the respiratory cycle. These measurements suggest that decelerating waveform ventilation may cause less barotrauma and can be used as an added source of protection to the airways in these patients.

One of the limitations of this study is the small number of subjects. Larger randomized clinical studies are needed to provide support of the results of this study. Another limitation is short time of equilibration and short time on each of the waveforms. We do not know if a longer period of time might increase PaW, dpaW, and PEEPi but it should theoretically not cause major variations in pulmonary mechanics. Further clinical testing of respiratory mechanics with decelerating waveforms in different modes of ventilation is worth serious consideration. All the findings, thus far, support the hypothesis that this waveform may be more effective in the ventilation of critically ill patient with respiratory failure. The importance of delivering effective mechanical ventilation to critically ill patients with respiratory failure while avoiding associated lung injury or significant hemodynamic compromise cannot be overemphasized. It is possible that a small numeric advantage in respiratory parameters with decelerating waveform pattern can lead to a noticeable beneficial effect on clinical outcomes in critically ill patients with respiratory failure.

Correspondence to

Rafael Barrera, Long Island Jewish Medical Center. New Hyde Park, New York 11030 Tel: (718) 470 7645 Fax: (718) 962 2239 Email: rbarrera@lij.edu

References

1. Slutsky AS, Tremblay LN. Multiple system organ failure: is mechanical ventilation a contributing factor? AM J Respir Crit Care Med 157: 1721-1725, 1998
2. Ranieri VM, Suter PM, Tortorella C, De Trullio R, Dayer JM, Brienza A, Bruno F, Slutsky AS. Effect of mechanical ventilation on inflammatory mediators in patients with acute respiratory distress syndrome: a randomized controlled trial. JAMA 282:54-61, 1999
3. Tremblay L, Valenza F, Ribeiro SP, Li J, Slutsky AS. Injurious ventilation strategies increase cytokines and c-fos m-RNA expression in an isolated rat lung model. J Clin Invest 99:944-952, 1997
4. Muscadere JG, Mullen JB, Gan K, Bryan AC, Slutlsky AS. Tidal ventilation at low airway pressures can augment lung injury. Am J Respir Crit Care Med 149: 1327 1334, 1994
5. Rossi A, Gottfried SB, Higgs BD, Zocchi L, Grassino A, Milic-Emili J. Respiratory mechanics in mechanically ventilated patients with respiratory failure. J Appl Physiol 58(6):1849-58, 1985
6. Brower RG, Shanholtz CB, Fessler HE, Shade DM, White Jr. P, Wiener CM, Teeter JG, Dodd JM, Almog Y, Piantadosi S. Preospective, randomized, controlled clinical trial comparing traditional versus reduced tidal volume ventilation in acute respiratory distress syndrome patients. Crit Care Med 27: 1492-1498, 1999
7. Wong PW, Nygard S, Sogoloff H, Groeger JS, Barrera R. The effect of varying inspiratory flow waveforms on pulmonary mechanics in critically ill patients. J Crit Care 15:133-136, 2000
8. Bergmann NA. Effect of different pressure breathing patterns on alveolar-arterial gradients in dogs. J Appl Physiol 18: 1049-1052, 1963
9. Adams AP, Economides AP, Finaly WEI, et.al.: The effects of variations of inspiratory flow waveform on cardiorespiratory function during controlled ventilation in normo-, hypo- and hypervolemic dogs. Br J Anesth 42: 818-825, 1970
10. Baker AB, Colliss JE, Cowie RW: Effects of varying inspiratory flow waveforms and time in intermittent positive pressure ventilation, II: various physiological variables. Br J Anesth 49:1221-1234, 1977
11. Branson RD, Hurst JM: Effects of inspiratory flow pattern on airway pressure, ventilation, and hemodynamics (abstract). Respir Care 32:913, 1987
12. Modell HI, Cheney FW: Effects of inspiratory flow patterns on gas exchange in normal and abnormal lungs. J Appl Physiol 46: 1103-1107, 1979
13. Al-Saady N, Bennett ED: Decelerating inspiratory flow waveform improves lung mechanics and gas exchanges in patients on intermittent positive-pressure ventilation. Intensive Care Med 11:68-75, 1985
14. Baker AB, Thompson JB, Turner J, et al: Effects of varying inspiratory flow waveform improves lung mechanics and gas exchanges in patients on intermittent positive-pressure ventilation. Intensive Care Med 11:68-75, 1985 Ray C Jr,
15. Miodownik S, Carlon G, Groeger J, Howland WS. Pneumatic-to-electrical analog for high-frequency jet ventilation of disrupted airways. Crit Care Med 1984 Sep;12(9):711-2
16. Baker AB, Restall R, Clark BW: Effects of varying inspiratory flow waveform and time in intermittent positive pressure ventilation: Emphysema. Br J Anesth 54: 547-554, 1982
17. Banner MJ, Boysen PG, Lampotang S, et al: End-tidal CO2 affected by inspiratory time and flow waveform- time for a change (abstract). Crit Care Med 14: 374, 1986
18. Niranjan SC, Bidani A. Ghorbel F, et al: Theoretical study of inspiratory flow waveforms during mechanical ventilation on pulmonary blood flow and gas exchange. Comput Biomed Res 32:355-390, 1999
19. LaFortuna CL, Minetti AE, Mognoni P: Inspiratory flow pattern in humans. J Appl Physiol 54: 1111-1119, 1984
20. Smith RA, Venus B: Cardiopulmonary effect of various inspiratory flow profiles during controlled mechanical ventilation in a porcine lung model. Crit Care Med 16:769-772, 1988
21. Pepe PE, Marini JJ: Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: the auto-PEEP effect. Am Rev Respir Dis 126: 166-170, 1982
22. Shikora SA, Bistrian BR, Borlase BC, Blackburn GL, Stone MD, Benotti PN: Work of Breathing: reliable predictor of weaning and extubation. Crit Care Med 18: 157-162, 1990
23. Coussa ML, Guerin C, Eissa NT, Corbeil C, Chasse M, Braidy J, Matar N, Milic-Emili J: Partitioning of work of breathing in mechanically ventilated COPD patients. J Appl Physiol 75: 1711-1719, 1993
24. Fiastro JF, Habib MP, Shon BY, Campbell SC: Comparison of standard weaning parameters and the mechanical work of breathing in mechanically ventilated patients. Chest 94:232-238, 1988
25. Rossi A, Gottfried SB, Zocchi L, Higgs BD, Lennox S, Claverley PM, Begin P, Grassino A, Milic-Emili J: Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation : the effects of intrinsic PEEP. Am Rev Respir Dis 131:672-677, 1985
26. Brandolese R, Broseghini C, Polese G, Bernasconi M, Brandi G, Milic-Emili J, Rossi A: Effects of intrinsic PEEP on pulmonary gas exchange in mechanically ventilated patients. Eur Respir J 6:358-363, 1993
27. MacIntyre NR, Cheng KCG, McConnell R: Applied PEEP during pressure support reduces the inspiratory threshold load of intrinsic PEEP. Chest 111:188-193, 1997
28. Fessler HE, Brower RG, Permutt S: CPAP reduces inspiratory work more than dyspnea during hyperinflation with intrinsic PEEP. Chest 108:432-440, 1995
29. Amato MB, Barbas CS, Medeiros DM, Magaldi RB, Schettino GP, Lorenzi-Filho G, Kairalla RA, Deheinzelin D, Munoz C, Oliveira R, Takagaki TY, Carvalho CR: Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome. N Engl J Med 338:347-354, 1998
30. de Durante G, del Turco M, Rustichini L, Cosimini P, Giunta F, Hudson L, Slutsky AS, Ranieri VM: ARDSNet lower tidal volume ventilatory strategy may generate intrinsic positive end-expiratory pressure in patients with acute respiratory distress syndrome. Am J Respir Crit Care Med 165:1271-1274, 2002
31. Yang SC, Yang SP. Effects of inspiratory flow waveforms on lung mechanics, gas exchange, and respiratory metabolism in COPD patients during mechanical ventilation. Chest. 2002 Dec;122(6):2096-104.
32. Guerin C, Lemasson S, La Cara MF, Fournier G. Physiological effects of constant versus decelerating inflation flow in patients with chronic obstructive pulmonary disease under controlled mechanical ventilation. Intensive Care Med. 2002 Feb;28(2):164-9.
33. Nilsestuen JO, Hargett KD. Using ventilator graphics to identify patient-ventilator asynchrony Respir Care. 2005 Feb;50(2):202-34.
34. Gabriella de Durante, Monica del Turco, Laura Rustichini, Patrizia Cosimini, Francesco Giunta, Leonard D. Hudson, Arthur S. Slutsky and V. Marco Ranieri. ARDSNet Lower Tidal Volume Ventilatory Strategy May Generate Intrinsic Positive End-Expiratory Pressure in Patients with Acute Respiratory Distress Syndrome American Journal of Respiratory and Critical Care Medicine2002. Vol 165. pp. 1271-1274.
35. Vieillard-Baron A, Prin S, Augarde R, Desfonds P, Page B, Beauchet A, Jardin F. Increasing respiratory rate to improve CO2 clearance during mechanical is not a panacea in acute respiratory failure. Crit Care Med. 2002;30:1407-1412.
36. Nicolò Patroniti and Antonio Pesenti. Low tidal volume, high respiratory rate and auto-PEEP: the importance of the basics. Crit Care. 2003; 7(2): 105-106.

Author Information

Rafael Barrera, M.D.
Surgical Critical Care Service, Long Island Jewish Medical Center

Natalie Gabovich, M.D.
Surgical Critical Care Service, Long Island Jewish Medical Center

Helen Sogoloff, M.D.
Surgical Critical Care Service, Long Island Jewish Medical Center

Jeffrey Groeger, M.D.
Urgent Care Center, Memorial Sloan-Kettering Cancer Center

Saul Miodownik, M.D.
Department of Medical Physics, Clinical Engineering Service, Memorial Sloan-Kettering Cancer Center

Download PDF

Your free access to ISPUB is funded by the following advertisements:

 

BACK TO TOP
  • Facebook
  • Google Plus

© 2013 Internet Scientific Publications, LLC. All rights reserved.    UBM Medica Network Privacy Policy