Catheter Virtual Lumbar Discectomy (The Epidural Cocktail For Lumbar Disc Prolapse)A New Minimally Invasive Alternative, On An Outpatient Bases
M Eldin
Keywords
catheter, cocktail, degenerative spine, epidural drugs, lumbar disc, minimally invasive.
Citation
M Eldin. Catheter Virtual Lumbar Discectomy (The Epidural Cocktail For Lumbar Disc Prolapse)A New Minimally Invasive Alternative, On An Outpatient Bases. The Internet Journal of Minimally Invasive Spinal Technology. 2012 Volume 5 Number 1.
Abstract
Introduction
Low back pain (LBP) is the commonest condition affecting the lumbar spine. Around 80% of the population experience at least once LBP in their lifetime. The most frequent cause of LBP with sciatica is the disc herniation. The natural history of herniated disc is characterized by disappearance of symptoms in up to 50% of patients, with shrinkage of the disc herniation revealed by MRI within 8 to 9 months after the onset of pain. However, not all patients can wait so long before symptoms improve. 1-6 An initial period of nonoperative management is recommended in such cases. After six weeks of nonoperative management, some patients will have persistent pain and will require additional treatment. Surgeries available do not offer clear, safe options free of complications in all cases. Moreover, some reported postoperative complications are more difficult to treat than the original illness.7-9
Epidural injections, described by Evans in 1930, have been used in the treatment of disc disease for over 80 years and epidural steroids for over 50 years. The procedure has been traditionally performed using a blind technique without fluoroscopic guidance, as described by Barry and Kendal. 10,11 Because of many favourable reports, epidurals have been increasingly used. The results obtained from many published studies, suggest a more rational use of that treatment. Several large epidemiologic studies have demonstrated safety and efficacy of this root of therapy in properly selected cases. Safety of epidural route has been well documented and enhanced by avoidance of accidental injection of large doses intravascularly, by continuous monitoring of blood pressure and respiration, and by avoidance of this technique in the presence of anti-coagulation. However, epidural root of drug administration has been remarkably stagnant over at least 25 years, with no new drugs developed for epidural administration. Existing agents used include local anesthetics, analgesics, and steroids. 10-19
I am introducing a new modification of that type of therapy, named (catheter virtual discectomy – CVD). Presenting our experience with this new modified procedure in which epidural catheter is used to deliver epidural cocktail of drugs into the desired target (the prolapsed disc and its surroundings), describe the technique of this relatively painless outpatient procedure, and present the complications we encountered. Delivering a unique drug cocktail to deal with the pathology of lumbar disc disease is finally evaluated.
Materials And Methods
Patient Selection
In the current study, patients were prospectively selected to receive CVD. The diagnosis was confirmed by radiographic studies. To qualify for the study, the patients should understand all other treatment options, the results and complications of current treatment, and choose the current treatment. Patients were selected for epidural cocktail injections by a single neurosurgeon. Inclusion criteria include patients with lumbar back pain with or without radicular pain of more than six weeks duration after ruling out infectious or neoplastic causes, and who have had MRI-proven intervertebral disc herniation and refractory pain, even after a full dose of medical and physical therapies for more than four weeks duration. None of our patients had previous low back surgery. All had tried full tolerable dose of anti-inflammatory drugs, muscle relaxants, pain killers, and antioedema medications for at least four weeks and physical modalities had failed to show an acceptable response. Exclusion criteria include patient’s lack of compliance and/or signs or symptoms denoting any underlying infection, bleeding tendency or malignancy. Patients with previous back surgery were excluded from the study. No patient had a frank instability. Because this series is prospective, with patients under the care of a single neurosurgeon, there were no variations in the selection, technique or follow up criteria.
Patient Population
A prospective series of 60 patients treated with epidural cocktail injections up to the end of 2009 was evaluated. All patients had undergone a thorough medical history and physical examination. All patients had undergone MR imaging before the procedure. All available imaging studies were reviewed before injections administered. Patients were informed of potential risks associated with the procedure before intervention. Patients also completed a pain scale survey. After completing the history-taking and careful neurological examination, the patient was categorized into one of the study groups.
Patients were categorized into three clinical groups on the basis of clinical presentation in order to assess the efficacy of treatment.
(A) Acute Group: 22 patients with an acute onset less than 6 months, with no past history of sciatica.
(B) Recurrent Group: 18 patients with a history of recurrent attacks of sciatica, previously completely cured by conservative treatment.
(C) Chronic Group: 20 patients with a gradual onset of symptoms or a history of more than 6 months and with a poor response to conservative treatment.
The Procedure
The skin is prepped in a sterile fashion using povidone-iodine (Betadine) followed by an alcohol rinse, after which a fenestrated drape is applied. Local anesthetic (1% lidocaine) is generally not needed and is only rarely injected subcutaneously, in sensitive patients. A stainless steel 18-gauge Tuohy epidural needle is advanced into the epidural space via a posterior approach. The puncture site is typically 2 to 3 cm caudal to the intended point of entry into the dorsal epidural space (Fig 1). An interlaminar technique at L3, L4, or L5 was used for most patients. The primary target for injection was at the L4–L5 level, unless any technical problems pushed the operator to the L3–L4 level. A total volume of 10–20 ml was separately injected per injection. The patient was trained to change his or her position every ten minutes after injection for better access of the drug to the diseased area. However, patients are kept in bed, in 45 degree position for at least 2 hours post-injection, and to have absolute bed rest for a week after the last injection.
Fig.1: CT axial cuts at the level of CVD placement showing the epidural catheter (A) entering the epidural space (B) through the interlaminar window. The space is well demonstrated around the dural sac; with the catheter appearing as a signal void (C). The catheter can also be visualized (D) on plain fluoroscopy.
Insertion Technique
Interlaminar Lumbar Epidural Catheter Placement
The catheter is inserted in the affected segment, through the fenestra interlaminaris to the target location. Two different techniques for interlaminar needle insertion were used.
Patients were grouped into 2 different catheter insertion groups, image-guided and blind insertion groups.
1. Image-guided Group: The patient is placed in a prone or lateral position on a fluoroscopy table, or CT table and the target spinal anatomy is assessed with the use of a high-resolution images. Assessment of epidural anatomy on MRI facilitates the choice of site for needle placement. The insertion is ideally started on level above, and targeted to the level of greatest disease and pain symptoms, unless there are mitigating circumstances, such as wet or bloody tap, that direct to an alternative insertion site. The intended puncture site may be initially marked on the skin with the C-arm unit in the appropriate orientation. Post-injection films are then obtained to document dispersal of injectate and to demonstrate possible epidural space abnormalities.
2. Blind insertion Group: The distance of lumbar interspinous space to epidural space is normally 2–7 cm long. The epidural needle is inserted into the skin and advanced while a syringe containing a bubble of air was attached to it. Epidural space was sensed using “loss of resistance” method and confirmed after sensory (numbness) evidence of the proper injection site. This was achieved following free flow of 2–4 ml of 2% lidocaine.
In early cases, to document accurate needle placement and to evaluate the epidural space before the instillation of therapeutic substances, in both groups, variable amounts of radiologic contrast material under direct fluoroscopic observation were injected before therapeutic injection, provides improved safety and efficacy. The risk of unintended intrathecal injection and its consequences can be virtually eliminated. Moreover, the practice of soft tissue injections outside the epidural space can be avoided. After checking free flow of saline into the epidural space, the catheter will be fixed and covered with sterile bandage.
Expected epidural blockage may alter the distribution of injected materials and thus explain a patient’s response whether unilateral or limited epidural block or a complete block is encountered. In such cases, subsequent injections at a more caudal or cranial location may prove effective to ensure widespread, dispersal of the injectate and to maximize delivery of therapeutic substances to the foramen and epidural space nearest the suspected target disorder. We attempt to perform our CVDs at or as near as is possible to the segmental disease exhibited on imaging studies.
The Injected Cocktail
For a period of 2-5 days, mostly 3 days, multiple injections of analgesic and anti-inflammatory, osmotic, (± enzymatic) cocktail of drugs will be instilled. These drugs acting together block pain, decrease inflammation, reduce swelling of the affected root and shrink the bulged disc volume. Following every injection, the patient is kept under supervision for at least one hour to assess initial therapeutic response to the injected drugs, if any. Sedation and cardiac monitoring of patients were not needed in this series. On the last day the catheter will be removed, taking care to see its tip out. During the whole procedure, an antibiotic cover with an effective broad spectrum antibiotic is given, and continued for 2 more days after catheter removal.
Outcome Assessment
Care and follow-up during and after injection require familiarity with the side effects and complications that might develop in relation to the procedure and/or cocktail components. The procedure-related calls should be suspected before its occurrence. Knowledge of common side effects, complaints, questions, and possible significant complications is an essential part of the procedure. We contact patients between 3 and 7 days after their epidural injection to assess therapeutic response and any unwanted sequelae. If there are any unusual complaints or circumstances, additional follow-up is then provided. After one week, one month and every 3 month thereafter, the pain was assessed using visual analogue score (VAS). Any decrease in VAS of more than two scales was defined as a significant VAS improvement. Patients were screened for any major or minor complications. The patients were then followed for one up to three years to determine the outcome of treatment.
Results
Of the 60 patients studied, there were 35 male (58.3%) and 25 female (41.7%) patients with ages ranging from 17 to 52 years, with a mean age of 32 years. The duration of pain to epidural injections ranged from 6 weeks to 36 months.
Clinical Outcome
Success of CVD is defined as a very substantial improvement as regards pain, spinal mobility and straight leg raising, maintained for the period of follow-up. Failure is defined as either no improvement or a temporary or moderate improvement with recurrence of symptoms after continuation of daily activities.
The overall VAS improvement for two weeks and three months after CVD were 65.4% and 58.3%, respectively. In all the three clinical groups, remarkable improvement in one-month VAS based on low back and radicular pain occurred in 45 (75%) patients. VAS values for the acute, recurrent and chronic groups were different at two weeks and three months post-injection periods. Better results were obtained from patients from the acute and recurrent groups after one month. Even though, slightly better results were obtained in the two-week follow-up in the acute group. On the other hand, differences in VAS improvement in the second week, one month, and three month follow-up was less in the chronic group. In the chronic group, 4 cases complained of pain aggravation after CVD, 8 cases had improvements of less than two scores [mild to moderate] and the remaining 8 cases felt neither remarkable improvement nor worsening in pain perception during the follow-up period.
Nine patients (15%) who showed improvement followed by relapse had a second epidural and of these, 6 patients (10%) benefitted from the second injection and were classed as successes. It can be seen that there was a significant improvement in the success rate in patients having their epidural within 6 months of the onset of symptoms and those in the “acute” category.
The presence of degenerative changes on plain X-ray of the lumbar spine, mostly in the chronic group, did affect the results of CVD treatment. The more the mechanical bony affection, the less favourable is the result. Variations in the injection technique did not affect the results of the treatment but variations in the protocol of the injection appeared to affect the results in acute cases.
The present series showed 80% success rate in “acute group”, 60% in “recurrent group” and 40% in “chronic group” cases; the acute and recurrent patients having CVDs within 6 months of the onset of symptoms, the chronic patients, having had symptoms for longer than 6 months when given their CVDs.
As expected, most patients reported that the treatment was a good choice and could be repeated if needed. Patients for whom CVD had failed and who then underwent discectomy did as well as the patients in the original study.
Access Failures
In one patient, a wet spinal tap precluded access to the epidural space. Another higher catheter insertion was done, without any subsequent drug instillation for 24 hours. This patient was treated routinely thereafter using our standard protocol, which most likely would have circumvented this obstacle. In 9 cases, catheter obstruction necessitates another catheter insertion. One of them was obstructed immediately after insertion. That is why, routine check of free flow of saline along the catheter before injection is mandatory. Accidental catheter extrusion occurred in another 3 cases, in which another catheter has to be inserted. Failure of access the interlaminar gap was not recorded.
Complications
Reported complications occurred early in our experience. There were no major complications including epidural haematoma or abscess formation. There were no local or epidural infections in this series. None of these patients had other delayed complications. The overall incidence of minor complications in all groups were transient hypotension and vomiting in two cases (3.3%), flushing in six cases (10%), cerebrospinal fluid (CSF) hypotension secondary to dural puncture in one case (1.7%) (five cases had headache without any CSF leak), and transient sensation of chest compression in five cases (8.3%).
Significant transient hypotensive episode reported in one patient, recovered few minutes later. The other patient had vomiting with a severe vasovagal response after injection due to rapid injection, in the sitting position. She was observed for 3 hours in the emergency department, with no residual complications. Her back pain was nevertheless dramatically relieved by the procedure. That is why, slow injection technique is mandatory, in the lying down posture, to avoid such a complication.
Radiological Outcome
(Fig.2 to Fig.6)
Reviewing the radiological follow up images of all the study cases at different follow up visits, clinical improvements was associated with definite radiological improvement in the form of definite volume decrease of the bulged, or prolapsed disc material, as shown clearly in figures 2 to 6. On the other hand, the absence of clinical improvement was associated with no radiological changes. Cases with recurrence of symptoms had either no radiological changes or mild volume changes, not enough to result in definite clinical change.
Figure 2
Figure 4
Figure 5
Figure 7
Figure 8
Discussion
Lumbar discogenic pain (LDP) could be related to mechanical and inflammatory causes. The inflammatory causes include immune response to the protruded disc material in the form of cell-mediated, biohumoral factors and inflammatory enhancers. Thus, logically speaking, anti-inflammatory medications are the corner stones in the treatment of that type of pain.
Regarding the mechanical causes of LDP, they are both direct (compression of the nerve roots, deformation of the ligaments and annulus, and stimulation of the nociceptors of Luschka’s nerve of the posterior root of the spinal nerve), and indirect (ischaemia due to arterial compression, and venous stasis). To counteract these mechanical effects, the unique microstructure of the intervertebral disc (IVD) should be understood. The IVD has a heterogeneous structure made of two different regions, namely the annulus fibrosus (AF), and the nucleus pulposus (NP). The nucleus appears macroscopically cloudy and jelly-like and is composed mostly of water, collagen and proteoglycans. The annulus is similar in composition to the nucleus, with less water and a greater amount of collagen. The annulus has a laminar structure that is regular on the outer most regions of the IVD with thick lamellae, but begins to lose some laminar structure closer to the nucleus. The IVD is populated by chondrocyte-like or fibrochondrocyte-like cells of mesenchymal origin in all zones as well as larger, highly vacuolated notochordal cells present only in the NP. These cells are responsible for the synthesis of the IVD matrix during development and maintenance of the extracellular matrix throughout life. 1, 2, 5, 20-25
The idea of the present study is to have a new drugs mixture by which we can alter, virtually, without any invasive or even minimally invasive structural intervention, the lumbar disc disease scenario, and manage the presenting clinical and radiological pictures. We took into consideration important findings of previous studies, namely, successful epidural steroid injection (ESI) alone, and volume changes in response to osmotic stresses.
Regarding ESI, some studies reported lumbar disc herniation regression after successful EPI alone. Patients who were successfully treated conservatively and whose pain decreased significantly within the first six weeks were found to have a larger number of resorbed extruded and sequestered disc herniations on follow-up magnetic resonance imaging (MRI). 26-28 Carette et al showed a slightly better improvement in leg pain over six weeks in a randomised controlled trial of ESI in patients with sciatica due to herniated discs. 29
Regarding disc volume changes, normally, the IVD under dynamic compressive loads shows diurnal variations in disc height and water content. The biophysical mechanisms involved are not fully understood, but are believed to involve changes in the interstitial osmolality or pH secondary to exudation of interstitial water. As the cell membrane is relatively permeable to water, increasing the extracellular osmolality leads to a decrease in cell volume. The mechanism by which IVD cells are able to transduce the applied osmotic stress is unclear. The response is triggered not only by the presence of an osmotic gradient, but rather by some downstream cellular response to the osmotic stress (cellular volume change, membrane stretch, and membrane depolarization). Within the IVD, zonal variations in the cellular volumetric response to hyperosmotic stress were also observed. The volume adaptation characteristics of NP differed markedly from those of AF. 30-41
Given these findings of volume changes in response to osmotic changes, our idea suggests that the addition of hyperosmotic media to the antioedema and anti-inflammatory media have a good chance of decreasing the volume of the prolapsed disc material. This hypothesis is supported by our findings of definite clinical and radiological improvement in properly selected cases. Reducing intervertebral disc size by chemical aspiration of water of the HIZ or partially shrinking the herniation by drying reduces the pressure on the torn annulus and creates a space for bulge regression whenever the tension of the annular fibres regain capacity to contain the disc. The proposed suggestion is that a small change in volume produces large change in pressure, and later allows healing of the annular cracks.
Widely differing results have been published by various authors using epidural injections, and various combinations of saline, local anaesthetic and steroid injections have been used and the results differ significantly even in series using the same medication. Revising these series, it was obvious that the precise selection of the cases is of importance in determining the results and indeed a look at published work shows that very little attempt has been made to relate the results of treatment to the precise cause of the symptoms and this almost certainly accounts for the differences in the results. 42-54
It is reasonable to assume that the earlier a CVD is given the more effective it will be, and that the more chronic the case is, the more the failure rate will be. Chronicity may indicate a tight mechanical compression, a nerve root infiltrated with chronic inflammatory cells, ischaemic root, or neuropathic type of pain that may need different treatment methodologies. This concept is borne out by the observations from the present series, i.e., a 60-80% success in all patients having CVDs within 6 months of the onset of symptoms, with only a 40% success in “chronic” patients, having had symptoms for longer than 6 months when given their CVD.
As most minimally invasive procedures, CVD needs only a short hospital stay, or even nonhospital, outpatient protocol. It also eliminates the risks of post-operative scarring linked to surgery which is responsible for recurrence of pain in many cases. CVD can also be repeated in the same patient leaving the anatomical corridors intact and normal if they should fail. The success rates reported in our study vary from 50 to 80% of excellent or good results, according to the selection criteria.
White and coworkers found that inaccurate needle placement occurred in 25% to 30% of blinded techniques, even in skilled and experienced hands. 55 Based on the high rate of erroneous needle placement described in the literature and the potentially devastating effects of intrathecal drug injection, we used to perform epidurography in conjunction with CVD in image-guided group of patients unless there is either a history or reasonable suspicion of allergy to iodinated contrast agents. It is a safe outpatient procedure that can assure correct needle placement and demonstrate anatomic features. 56,57 The use of 5 mL of water-soluble contrast material in order to adequately draw the epidural space is usually enough. However, in the present study, no significant difference was noted between the two groups in expert hands. Only early in the study the difference was significant. In the literature, the argument between the two insertion techniques holds true and this is especially important in our multi-session CVD technique. However, after doing a lot of these techniques and after evaluation of both interventionists and aneasthetists, it would be fair enough to say that if one masters the technique, either blind or image-guided, erroneous needle placement would be minimized. In skilled hands, our procedure ensures delivery of the therapeutic materials into the epidural space and prevents complications due to intrathecal or intravascular injections. 58-62
It is our practice to perform at least three consecutive epidural instillations. If there is any doubt, injectate delivery was shown to be accurate with epidurography. Another CVD can be repeated for nonresponders, if indicated. We have reviewed the efficacy of CVD in our daily practice and have confirmed a high rate of success of a non-invasive procedure on outpatient bases with low morbidity. Moreover, using CVD is justified by the patients. Before CVD, discussing the technique with the patient make them keen to try. After CVD, most of our patients have commented on the relatively painless nature of the procedure as compared with any other intervention. This is important as no patient was sedated before the procedure. So, cardiac monitoring is not required for CVD when performed under these circumstances. Thus, CVD is extremely safe and causes minimal patient discomfort, making the procedure ideally suited to outpatient settings. Performing CVD in an awake and fully alert patient virtually eliminates the potential for serious complications when done by skilled, experienced spine surgeon.
Conclusion
Despite the supposed argue, this series confirms the value of Catheter virtual discectomy (CVD) in the treatment of lumbar disc protrusions. The current study provides evidence that immediate pain relief and increase in function can be provided by CVD with a very low rate of morbidity. It is a safe & effective treatment for symptomatic lumbar disc herniations in nearly one-half, if not more, of the patients treated, with reported resolution of symptoms at the follow-up evaluations. The follow-up images showed, in addition to the clinical improvement, definite structural decrease of the disc bulges in a way as if discectomy was done without any surgical or interventional intervention. That is why the name catheter virtual discectomy (CVD) was introduced. Failures are largely due to continued mechanical pressure on the nerve root, especially with hard disc protrusions, in chronic cases. The significant increase in the success rate in acute cases (those who have an epidural within 6 months of the onset of symptoms) warrants the role of CVD in decreasing the volume of the compressing disc and decreasing its inflammatory effects. Importantly, this study also demonstrated that even for those in whom treatment with CVD failed, there did not appear to be any deleterious consequences due to the delay in operative intervention. The current study adds further credence to our belief that most patients with lumbar radicular pain without a profound neurologic deficit should first be offered CVD injection trial, especially in young patients.