Abstract

Pseudoaneurysm is a rare complication of synthetic vascular prostheses in hemodialysis patients. Rupture and life-threatening hemorrhage are the most common and dangerous complications of the pseudoaneurysm.

In this study, under the light of the current literature, we aimed to present our case of successful repair of pseudoaneurysm occurred at the arteriovenous hemodialysis access graft placed between right common femoral artery and great saphenous vein 6 months ago.

Ultrasound is useful in the evaluation of other graft or fistula abnormalities, such as pseudoaneurysm. The traditional repair of a clinically significant hemodialysis graft pseudoaneurysm is its surgical ligation or resection and it must be followed by insertion of a new interposition graft segment.

 

Introduction

The number of patients with end-stage renal disease has steadily increased(1). Improvements in hemodialysis techniques have lead to extended life expectancy. Thus, many patients require secondary and occasionally tertiary access procedures. In this situation, an arteriovenous bridge graft, usually with PTFE, continues to be a reasonable alternative form of hemodialysis access(1,2). The creation and maintenance of hemoaccess occupies a significant portion of most vascular and general surgery practices(3). Pseudoaneurysm is a relatively rare complication of synthetic vascular prostheses in patients on hemodialysis treatment and comes from a needle puncture. Anastomotic pseudoaneurysm is also rare(1). Pseudoaneurysm incidence is documented to be 2% to 10% of dialysis access graft(1).

Case Presentation

A 51-year-old man presented with swelling and pain in the right femoral region. He had been on hemodialysis for 3 years due to end-stage renal disease. The patient had been on hemodialysis treatments for 6 months with an arteriovenous graft between femoral artery and saphenous vein in the right lower arm. On physical examination, there was a pulsatile mass in the right femoral region . A murmur was detected on auscultation. Doppler examination revealed a feature in consistent with pseudoaneurysm. The size of pseudoaneurysm was 13 × 8 cm(Figure 1).

Figure 1
Figure 1

A longitudinal incision was made under general anesthesia and the pseudoaneurysm sac was explorated(Figure 2).

Figure 2
Figure 2

The right common femoral artery was controlled above the aneurysm sac. No infection was observed. When the aneurysmal sac was opened .The PTFE graft had separated from the femoral artery and thrombosed (Figure 3). Distal backflow was optimal.

Figure 3
Figure 3

There was a destructed segment of 6 to 7 centimeters in length at the native common femoral artery including the ostium of the deep femoral artery. The defect in the femoral artery was repaired secondarily with the interposition of a 8mm ringed polytetrafluoroethylene (PTFE) graft binding common and superficial femoral artery.In same session we performed a bypass procedure to deep femoral artery from this 8mm PTFE graft with a 6mm PTFE graft in an end-to-side fashion (Figure 4).

Figure 4
Figure 4

The distal arterial pulses were palpable postoperatively.He didn't have additional problem and he was discharged home with surgical success and without any complications at 6th day.

Discussion

In the management of end-stage renal disease vascular access may be achieved by a catheter, a native arteriovenous fistula, or a prosthetic graft. An arteriovenous fistula between the radial artery and the cephalic vein should be the primary choice for hemodialysis(1). When superficial veins may not be suitable for an arteriovenous fistula because they have already been used for repeated arteriovenous fistula procedures, an alternative is an arteriovenous graft using polytetrafluoroethylene (PTFE) to bridge between arteries and veins. However, PTFE grafts can lead to some complications, such as bleeding, dilatation, infection, pseudoaneurysm, seroma, steal, swelling, stenosis, or thrombosis(1,2).

The development of a hemodialysis graft–related pseudoaneurysm is a multifactorial pathological process(4). Repeated needle cannulation may cause disruption and fragmentation of the PTFE graft material . This is particularly true if the sites of cannulation are not uniformly distributed along the entire length of the hemodialysis graft(4,5).

Diagnosis of pseudoaneurysm was confirmed by Doppler examination for our patient. Duplex scan can correctly define the exact nature and extension of the aneurysm, permiting the differentiation from hematomas, seromas, lymphocele and abcess(1).

Progressive enlargement of a pseudoaneurysm can interfere with needle cannulation or lead to secondary complications including breakdown of the overlying skin, spontaneous bleeding, and rupture(4). The 2000 K/DOQI Guidelines recommend surgical repair if the size of the pseudoaneurysm limits the available cannulation sites or if the integrity of the overlying skin is compromised (4,6). The traditional treatment of a clinically significant pseudoaneurysm is surgical ligation or resection of the hemodialysis graft followed by insertion of a new interposition graft segment (4,7).

In conclusion; lower extremity AV dialysis access are associated with multiple complications and should probably be placed only if significant patient morbidity can be accepted and justified(8). Careful attention to technical detail is required, and avoidance of several diagnostic pitfalls is necessary(9). The traditional repair of hemodialysis graft pseudoaneurysms has been to surgically replace that segment of involved PTFE graft material or autogenous vein(4,7,10).

Correspondence to

Doç. Dr. Ufuk YETKIN, 1379 Sok. No: 9,Burç Apt. D: 13 - 35220, Alsancak – IZMIR / TURKEY Tel: +90 505 3124906 , Fax: +90 232 2434848 e-mail: ufuk_yetkin@yahoo.fr

References

1. Yasim A, Kabalci M, Eroglu E, Zencirci B. Complication of hemodialysis graft: anastomotic pseudoaneurysm: a case report. Transplant Proc 2006 ;38(9):2816-8.
2. Basaran O, Karakayali H and Emiroglu R, et al. Complications and long-term follow-up of 4416 vascular access procedures. Transplant Proc 2003; 35 : 2578.
3. Rodriguez HE, Leon L, Schalch P, Labropoulos N, Borge M, Kalman PG. Arteriovenous access: managing common problems. Perspect Vasc Surg Endovasc Ther 2005 ;17(2):155-66.
4. Vesely TM. Use of stent grafts to repair hemodialysis graft-related pseudoaneurysms. J Vasc Interv Radiol 2005 ;16(10):1301-7.
5. Delorme JM, Guidoin R, Canizales S, et al. Vascular access for hemodialysis: pathologic features of surgically excised ePTFE grafts. Ann Vasc Surg 1992; 6:517-524.
6. NKF-K/DOQI Clinical Practice Guidelines for Vascular Access. New York: National Kidney Foundation, 2001.
7. Lin PH, Johnson CK, Pullium JK, et al. Transluminal stent graft repair with Wallgraft endoprosthesis in a porcine arteriovenous graft pseudoaneurysm model. J Vasc Surg 2003; 37:175-181.
8. Taylor SM, Eaves GL, Weatherford DA, McAlhany JC Jr, Russell HE, Langan EM 3rd. Results and complications of arteriovenous access dialysis grafts in the lower extremity: a five year review. Am Surg 1996 ;62(3):188-91.
9. Lockhart ME, Robbin ML. Hemodialysis access ultrasound. Ultrasound Q 2001 ;17(3):157-67.
10. Najibi S, Bush RL, Terramani TT, Chaikof EL, Gunnoud AB, Lumsden AB, Weiss VJ. Covered stent exclusion of dialysis access pseudoaneurysms. J Surg Res 2002 ;106(1):15-9.

Author Information

Haydar Ya?a, M.D.
Specialist, Department of Cardiovascular Surgery, İzmir Atatürk Training and Research Hospital

Ufuk Yetkin, M.D.
Deputy Chief, Department of Cardiovascular Surgery, İzmir Atatürk Training and Research Hospital

Berkan Özpak, M.D.
Resident, Department of Cardiovascular Surgery, İzmir Atatürk Training and Research Hospital

Mehmet Bademci, M.D.
Resident, Department of Cardiovascular Surgery, İzmir Atatürk Training and Research Hospital

Kaz?m Ergüne?, M.D.
Specialist, Department of Cardiovascular Surgery, İzmir Atatürk Training and Research Hospital

Ali Gürbüz, M.D.
Clinic Chief, Department of Cardiovascular Surgery, İzmir Atatürk Training and Research Hospital

Your free access to ISPUB is funded by the following advertisements:

Advertisement
BACK TO TOP
  • Facebook
  • Google Plus

© 2013 Internet Scientific Publications, LLC. All rights reserved.    UBM Medica Network Privacy Policy